Short answer: Spin-exchange relaxation-free (SERF) magnetometers use a dense alkali-metal vapour in a very low magnetic field so that collisions between atoms stop destroying the spin signal. A 2002 experiment reported a potassium magnetometer with a sensitivity of 10 fT per root hertz, and a 2024 paper reported a chip-scale design with 20 fT per root hertz. Both are laboratory demonstrations.

What is the SERF regime?

The 2002 Physical Review Letters abstract says alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors, and that their sensitivity is limited by relaxation due to spin-exchange collisions. The authors demonstrate a potassium magnetometer in which spin-exchange relaxation is completely eliminated by operating at high potassium density and low magnetic field.

What did the 2002 experiment measure?

Direct signal-to-noise measurements give a sensitivity of 10 fT per root hertz, which the authors say is limited by magnetic noise from Johnson currents in the magnetic shields. They extend an earlier theoretical analysis of spin exchange in low fields to arbitrary spin polarizations and estimate the shot-noise limit of the magnetometer, though the estimated value did not render in the page text we read, so it is not quoted here.

What about caesium?

A 2008 Physical Review A paper describes a caesium magnetometer operating in the SERF regime. At a vapour cell temperature of 103 degrees Celsius the authors achieve intrinsic magnetic resonance widths of 17 microgauss, and they observe a narrowing effect from diffusion. Several of the sensitivity figures in that abstract did not render, so none are quoted. The abstract states that caesium has a higher saturated vapour pressure than other alkali metals, so SERF magnetometers using it are attractive where lower temperatures are needed, which is the authors' reasoning.

What did the 2024 chip-scale paper do?

The authors demonstrate a miniaturized single-beam hybrid optical pumping SERF magnetometer based on a microfabricated atomic vapour cell. Although the optically thin caesium atoms are spin-polarized, the dense rubidium atoms determine the experimental results. They report an enhanced signal strength and narrowed resonance linewidth, and a roughly five-fold suppression of optical noise using a differential detection scheme. They investigate how cell temperature affects the magnetometer parameters, and report an optimal sensitivity of 20 fT per root hertz. The authors say the work provides a foundation for chip-scale integration of highly sensitive quantum magnetometers for future magnetocardiography and magnetoencephalography applications. That is an outlook, and the abstract reports no medical measurement.

How to read this

The three papers are 22 years apart and use different alkali metals and cell designs, so their sensitivities are not a single trend. Sensitivities are the authors' own figures. This post is based on abstracts and visible summary text, and full texts were not checked. It makes no claim about products or clinical use.

FAQ

What does fT per root hertz mean?

Femtotesla per square root of hertz, a standard unit for magnetometer noise. The 2002 and 2024 abstracts report 10 and 20 in those units.

Why is spin exchange a problem?

It causes relaxation that limits the sensitivity of alkali-metal magnetometers, per the 2002 abstract.

Why use caesium?

Its higher saturated vapour pressure allows operation at lower temperatures, according to the 2008 abstract.

Is the chip-scale version used in medicine?

Not according to the abstract. Magnetocardiography and magnetoencephalography are named as future applications.

All field notes